L&T Star 55 Color Patient Monitor

L&T Star 55 Color Patient Monitor
Show larger view
Product Number: LAF386390061027
Quantity:   


 
THREE YEAR PARTS AND LABOR WARRANTY
 
DISPLAY
TYPE: High resolution color TFT display.
RESOLUTION: 800 X 600 pixels.
SIZE: 12.1" configurable screen for max of eight waveforms.
TRACE SPEED: 12.5, 20 OR 50 MM/SEC for ECG, SpO2 & IBP 6.25, 12.5 OR 25 MM/SEC for respiration & CO2.
 
OPTICAL ENCODER KEYS
 
OPTICAL ENCODER: Rapid access to all the functions and setting through single knob.
HOT KEYS: Quick action hot keys for acknowledge, NIBP start/stop, record start/stop, IBP zero, freeze, stand by, go-to, CO2 pump off and home key.
 
3/5 LEAD ECG MONITORING
Automatic detection of 3 or 5 lead ecg cable. Display of I, II, III with 3 - lead cable and I, II, III AVR, AVL, AVF andV leads with 5 lead cable. Built-in cautery and defibrillator protection. Optional st and arrhythmia analysis.
 
HR RANGE: 20 to 350 BPM
 
RESPIRATION
 
PRINCIPLE: Impedance pneumography. Display of respiration waveform with respiration rate.
RR RANGE: 4 to 150 BPM
 
TEMPERATURE
 
Simultaneous monitoring of two temperatures. Display of T1 ANand  T2 or ΔT (if difference between T1 & T2 is less than 9.9°C)
PROBE: Compatible with YSI 400 series temp. probe(optional)
TEMP. RANGE: 0°C to43°C
 
PULSE OXIMETRY (Nellcor module)
 
PITCH VARIATION: With change in oxygen saturation SpO2 range: 0-100%
DISPLAY: Plethysmograph, pulse strength & SpO2 values.
ACCURACY: Adult- 100 TO 70%   (+/- 2 digits), 0 to 69% (unspecified) (+/- STD. DEV.)
NEONATE: 100 TO 70% (+/- 3 digits), 0 TO 69% (unspecified)
PR RANGE: 20 TO 230 BPM +/- 3 BPM (+/- STD. DEV.)
 
INVASIVE BLOOD PRESSURE
 
Simultaneous monitoring of max. 4 channels. Display of systolic, diastolic and mean pressure. Individual and common channel zeroing. Labeling facility with automatic limits/gain/color setting. Pressure channel overlapping option available.
 
RANGE: -40 to 300 MMHG
IBP SCALE: 5, 10, 15, 20, 30, 60, 80, 100, 120, 150, 180, 200, 240, 300 & auto
 
NON-INVASIVE BLOOD PRESSURE (Suntech Module)
 
PRINCIPLE: Oscillometric
DISPLAY: Systolic, diastolic & mean pressure
MODES: Manual, stat (5 MIN), auto. (2 MIN TO 90 MIN)
RANGE: 20 TO 250 MMHG
ACCURACY: +/- 3 MMHG
 
CAPNOGRAPHY (Oridion Module)
 
Microstream capnography with display of CO2 waveform and digital values of EtCO2, FiCO2, & RR, CO2 ets priority for calculating resp. rate
EtCO2 RANGE: 0 - 99 MMHG
FiCO2 RANGE: 0 - 20 MMHG
GAIN: 20, 40, 60, 80 MMHG
FLOW RATE: 50 ML/MIN (-7.51 / + 15ML/MIN)
WARM-UP TIME: 40 SECS (typically)
UNITS: MMHG, KPA / VOL%, RR
RANGE: 0 -150 BPM
 
ALARMS
 
Alarm settings for all parameters
PATIENT ALARM:  Red flashing with audio and message indicator alarm tuo-set facility provided
EQUIPMENT ALARM: Yellow flashing with audio and message indicator
ALARM SUSPEND: Continuous yellow
RE-ALARM FACILITY: 3 min. for acknowledge alarm
 
TRENDS
 
72 HRS/100 Patients graphical and tabular trend withh zoom facility
NIBP TREND: 240 Reading tabular
ALARM RECALL: Last 24 alarm events with date, time & message
 
RECORDER (optional)
 
TYPE: Built-in channel thermal recorder for recording two waveforms (selectable) with numerical data and alarm status. nibp and tabular trend recording with patient information
MODES: Direct/delayed/continous ans record on alarm facility(selectable)
 
DIMENSION: (H X W X D) 208 X 320 X 158 MM
WEIGHT: 6KG (with built-in battery & thermal array recorder)
 
POWER SUPPLY
 
UNIVERSAL POWER: 95 - 265V AC, 50/60 Hz
CURRENT RATING: 0.7 A (MAX)
BATTERY TYPE: 14.8V (4 AH/8 AH) Lithium Ion Batteries
OPERATING TIME: Built-in rechargeable battery for 2/4 hrs of continuous operation under full charge condition (typically)
CHARGING TIME: 8 HRS (typically)