L&T Star Color Medical Monitor
FIVE YEARS PARTS AND LABOR WARRANTY
Display:
High resolution color TFT: size (10.4" diagonal)
Resolution: (640 x 480 dots)
Excellent viewing from distance and angle.
Sharp and high contrast TFT display technology.
Waveform Field:
Configurable screen for max. four waveforms, (ECG, SpO2, Resp., Invasive BP or CO2). Possible to view any 4 ECG leads, if 4 lead ECG cable is connected (5 lead version).
Digital Field:
HR/PR, SpO2, T1, T2 or ?T , IBP1, IBP2 & NIBP (sys., Dia., Dia., MN), EtCO2 and FiCO2 on screen display of alarm limits/status.
Trace Speed:
12.5, 25 or 50 mm/sec for ECG, Invasive pressure wave forms and Plethysmopraph. 6.25, 12.5 or 25 mm/sec for respiration and CO2.
Optical Encoder:
Rapid access to all the functions and settings of parameters through single-knob. Quick action hard for alarm mute, NIBP start/stop, IBP Zero, Freeze and return to main screen.
3/5 lead ECG Monitoring:
Automatic detection of 3 or 5 lead ECG cable. Display of I, II, III aVR, aVL, AVF and V for 5 lead mode. Built-in cautery and defibrillator protection.
HR range: 30-270 bpm
Monitoring: 0.5 Hz - 100 Hz
Diagnostic: 0.05 - 100 Hz
Respiration:
Impedance pneumography principle. Display of respiration wave form with respiration rate.
Respiration rate: 5 to 150 bpm
User selectable aponea alarm delay: 5 to 90 seconds (in steps of 5 seconds).
Temperature:
Simultaneous monitoring of 2 channels. Dual temperature display, T1 & T2), with T if difference is less than 48ºF (9ºC)
Temperature range: 53 ºF to 109.4 ºF (12 ºC to 43 ºC)
Pulse Oximetry:
Pitch variation with change in oxygen saturation.
SpO2 range: 0 - 100%
Display of pulse strength, plethysmograph and SpO2 values.
Accuracy:
100 to 70% (+/- 2 digits)
69 to 50% (+/- 3 digits)
49 to 0% (unspecified)
Accuracy in neonatal monitoring 100 to 70% (+/- 3 digits).
Non-Invasive Blood Pressure:
Oscillometric principle. Display of Systolic, Diastolic & Mean.
Modes: Manual, STAT (continuous 5-minute operation) and Automatic (time interval 2-minutes to 90 minute selectable).
Alarm Limits selection possible for Systolic & Diastolic.
Range: 20 to 255 mmHg
Accuracy: +/- 5 mmHg
Alarms:
Alarm setting for all parameters.
Patient alarm: RED Flashing with audio and message indicator.
Equipment alarm: YELLOW flashing with audio and message indicator.
Alarm suspend: Continuous YELLOW.
Auto setting of alarms for HR/PR, SpO2, IBP1, EtCO2, FiCO2, Respiration and temp.
Silencing: 3 min for current alarm only.
All age groups advisory/warning.
Alarm recall: last 16 alarm events with time, date and message
Trends:
24 hrs of graphical and tabular trend for HR/PR, SpO2, IBP, EtCO2, FiCo2, Resp. and Temp.
NIBP trend: 240 readings tabular
Trends: 30-second storing. 2-hour zoom for graphical trends with mark and print facility. Date Time stamping for trends.
Recording:
Printing of single lead ECG, Numerical data and patient information on ink-jet printer.
External recorder connection available.
General:
Dimension: 8" H x 12.2" W x 9.05" W (202 x 310 x 230 mm)
Weight: 16.5 lbs (7.5 Kg), with built-in batteries. Direct interface possible with "SKYLINE" Multi-lingual option available.
Power Supply:
Universal power: 110V/230V AC, 50/60 Hz
Power ratings: 60W
Built-in, rechargeable battery for 2 hours of continuous operation under ideal & full-charge condition (typical).
Battery type: 6V 4Ah lead acid - 2 nos
Charging time: 12 hours (typical)
Ambulatory monitoring possible with car battery interface.
Designed to meet the requirements of Following international standards:
Class 1, Type CF of IEC 601-1
Level 2 of IEC 1000-4-4 and IEC 10004-5
**OPTIONS**
Capnography (CO2):
Side-stream Capnography with display of CO2 wave form and digital values of EtCO2 and FiCO2. CO2 gets high priority for calculation respiration rate. Gain 20, 40, 60, and 80 mmHg. CO2 measurement is possible in mmHg/Kpa/Vol%
Flow rate: 140 ml/min
EtCO2 range (mmHg): 5 - 80 (high) 0 - 60 (low)
FiCO2 range (mmHg): 2 - 20 (high)
Aponea alarm delay: 30 second non-selectable
Invasive Blood Pressure:
Simultaneous monitoring of 2 channels. Systolic, Diastolic & Mean pressures with respective wave forms of IBP1 & IBP2. Individual and dual channel zeroing. Labeling facility with automatic limit setting. Channel overlapping option.
IBP range: 300,150,60,30,20 and 10 mmHg
Measuring range: -40 to 300 mmHg
|